Known Issues in Lightbits 3.15.1
ID | Description |
|---|---|
48532 | The node-manager service can fail to start if the number of drives present falls below the minimum required for the node's configured layout, for example, after a drive failure, power loss or planned maintenance. In earlier releases, the node started with the missing drive marked as failed; in affected releases it does not start at all. Workaround: Set |
48435 | On some AMD EPYC servers, NVMe SSDs can report I/O timeouts. This can cause a storage node to be marked as failed, and while the node is out of service, volumes with reduced protection can become read-only. Workaround: Disable PCIe Relaxed Ordering in the server BIOS. |
47300 | If the cluster manager's connection to the cluster's internal coordination service is interrupted (for example, due to a leader change, network disruption, or a brief service restart), the cluster manager's view of cluster servers can stop updating entirely, with no automatic recovery. Workaround: Restart the cluster-manager service to restore normal operation. |
45157 | During a node power-up after an abrupt shutdown, the node's reported power-up progress can reach 100%, drop back to 50-60%, and then climb to 100% again. This affects the reported percentage only. Recovery completes correctly, and the node returns to service only when it is actually done. No workaround is needed. |
44673 | In rare cases, performing a KEK rotation while simultaneously executing a high volume of volume/snapshot control plane operations could result in increased etcd contention. This affects only customers utilizing cluster-level encryption with the KEK rotation API. |
44435 | pmem_init and lbe executables are linked using staticx and therefore require /tmp to be mounted with the exec option enabled; otherwise, these executables will fail to run with "permission denied". |
44383 | When cluster-level encryption is enabled, deleting a server that hosts the active Cluster Manager (CM) could prevent subsequent server additions from completing successfully. After removing such a server from the cluster, stop the CM service on it or shut the server down. |
44334 | In affected versions, stopping or restarting the node-manager service on a server (for example, during maintenance or an upgrade) can leave the data-path service hung while it waits for a configuration update that never arrives, which delays or blocks the server's shutdown. This issue is fixed in v3.18.3 and v3.21.1. |
42614 | Cluster manager and etcd services could suffer a very slow potential memory leak in rare cases. Mishandling of a deprecated GFTL data loss event could cause the event clean logic to stop cleanup of old events, leading to a continuous increase in the number of events stored on the cluster. |
42309 | In rare cases, a CM failover occurring during the initial KEK rotation process may result in a race condition where the new CM fails to become active, causing some API calls to fail. The data path remains unaffected as long as all nodes are healthy. |
42282 | A volume protection state might be reported incorrectly in the API as fully protected instead of degraded or read only, following a permanent failure re-balance that fails. The issue is limited to the protection state the API reports, but internally the protection state is handled as expected. |
41873 | Under a specific race condition, if a snapshot is created while a node is down and subsequently deleted during a very precise window in the node's startup sequence, the node may become unavailable. |
41466 | Creating a snapshot with a retention time greater than 192 years will fail and cause the API service to restart. |
41162 | Deleting a snapshot while a node is inactive could cause a subsequent rebuild initiated from that node (acting as primary) to fail. This condition can occur when the inactive node retains metadata for the deleted snapshot while peer nodes do not. Full (migration) rebuilds are more likely to be impacted, as they could include objects associated with the affected snapshot. If this issue is encountered, contact Lightbits Support for an approved procedure to identify and release the problematic snapshots. |
41095 | The |
40883 | When using the vCenter Plugin (VCP) to upgrade a cluster to Lightbits 3.17.1 or later, the upgrade fails because VCP cannot parse the updated version format. To complete the upgrade, use the Lightbits core CLI or REST API directly. |
40293 | When an admin-endpoint is deleted or updated, the corresponding iptables rules created for it remain in place. As a result, the related ports stay open even though the admin-endpoint has been deleted or updated. The iptables configuration is refreshed only after a service restart, instead of being properly updated in real time. |
40068 | In rare cases, a newly-created volume could be assigned the same NSID as an existing volume. This condition can lead to incorrect delete or update operations for volumes sharing the same NSID. If this issue is encountered, contact Lightbits Support for a manual remediation procedure to identify and fix the affected volumes. |
39742 | In rare certain circumstances, volumes protection state may fail to be updated correctly, due to an internal race condition that could lead to very temporary resource inconsistency that will fail the protection state update. |
39628 | To prevent a rare potential Machine Check Exception (MCE) and forced reboots on Sapphire Rapids machines, we recommend disabling the DSA offload feature. This condition can occur if the frontend log indicates "Enabling DSA crc32 offload for reads," and can be prevented by adding dsa_read_crc32: false and dsa_write_crc32: false under the "configurator" section of |
39211 | When deleting the most recent snapshot of a volume while a node holding a replica is offline, recently written data could revert to the data stored in that snapshot if the node later becomes the primary. |
38497 | When creating a new server to replace another server in the cluster using the --extend-cluster=false flag (which is the default setting), and at a much later time this server and its node experience a permanent failure and fail in place is enabled (causing the servers resources to be migrated), if the server goes active again it might not participate in all proper distribution of replicas over the cluster and could cause an imbalance of resources. |
38043 | For 3.14 & 3.15.1 If encryption was turned on but enabling it failed - resulting in the creation of an ' |
37852 | List connected hosts could return hosts that are not connected to a volume when a volume uses IP-ACL. Listing the connected hosts with a volume filter could return a host that is connected to the nodes the volume is replicated to (if other volumes exist that have ACL or IP-ACL matching this host, running over the same nodes) - even if this volume's IP-ACL does not match this host. |
37831 | In some cases, silent data corruption on an SSD could cause a node crash instead of attempting to recover the data and reporting an event. This can occur if the SSD returns invalid data rather than an I/O error. |
37830 | In extremely rare cases, a node may not recover to an active state if an I/O error or bad block is encountered on an underlying SSD during its startup sequence. This prevents a key service (gftl) from initializing correctly and may require manual intervention (such as removing the failed SSD from the system) to allow the node to complete its recovery successfully. |
37738 | Under certain scenarios, Lightbits will cause the grub package to be updated during Lightbits installation, including the addition of new servers. On RHEL8 and derivatives, after updating Grub from "grub2-2.02-162.el8_10" to "grub2-2.02-165.el8_10", if the system is using BIOS mode it might enter the "grub rescue>" prompt upon booting. When this happens, see https://access.redhat.com/solutions/7118853 for how to restore system boot to normal operation. |
37505 | In a rare combination of events, the |
37187 | In some rare cases, the frontend process shutdown may hang and never reach |
29683 | Systems with Solidigm/Intel D5-P5316 drives may experience higher than expected write latency after several drive write cycles. Contact Lightbits Support if you use Solidigm/Intel D5-P5316 SSDs and are experiencing higher than expected write latency. |
28027 | In specific circumstances, the server upgrade status may not reflect the correct state after a successful retry. This occurs in the following sequence: 1. A server is upgraded to version x.y.z. 2. The operation fails (for example, due to a timeout); however, the server binaries are successfully updated to version x.y.z. 3. The upgrade is retried to version x.y.z — this step is skipped internally, as the binaries are already up to date. 4. The upgrade status continues to show the previous failed operation, even though the retry completed without error. |
25382 | Under the conditions below, the amount of storage occupied by cold units (filled with 4096 small objects), is not accounted for and not reported, which could result in reaching a storage full or almost full situation that is not observable in the node storage statistics: - A sufficient amount of logical user storage contains highly compressible data; e.g., zeroes. - This data has been written in large chunks over a short period of time. - During this time, no or almost no user writes with lower compression rates or to uncompressed volumes. - The highly compressed data written remains unmodified (cold); i.e., not overwritten by user writes for a long period of time. When such a situation occurs, the control plane software does not detect storage capacity reaching the threshold to start proactive rebalancing to free capacity. The System Administrator also relies on the same storage statistics the control plane exposes, and therefore cannot tell that the system capacity has reached the limit. |
22582 | A server could remain in "Enabling" state if the enable server command is issued during an upgrade. |
19670 | The compression ratio returned by get-cluster API will be incorrect when the cluster has snapshots created over volumes. The calculation of the compression ratio at the cluster level uses different logic for physical used capacity and the amount of uncompressed data written to storage. Hence the compression ratio value might be higher than the actual value. A correct indication of cluster level compression can be deduced from a weighted average of compression ratio at the node levels; i.e., Compression ratio = sum(node compression ratio * node physical usage) / sum(node physical usage). |
18966 | "lbcli list events" could fail with "received message larger than max" when there are events that contain a large amount of information. Workaround: Use the --limit and --since arguments to read a smaller amount of data at a time. |
18948 | The node local rebuild progress (due to SSD failure) shows 100% done when there is no storage space left to complete the rebuild. |
18522 | When attempting to add a server to a cluster using lbcli 'create server' or rest post '/api/v2/servers", and the operation fails for any reason, 'list servers' could permanently show the new server in 'creating' state. |
18214 | Automatic rebalancing features (fail-in-place and proactive-rebalance) should be disabled if |
17298 | The migration of volumes due to automatic rebalancing could take time, even when volumes are empty. |
15715 | During a volume rebuild, the Grafana dashboard does not show the write IOs for the recovered data. |
14995 | A single server cluster cannot be upgraded using the cluster upgrade command. Upgrade using only the upgrade server command. |
14889 | In case of an SSD failure, the system will scan the storage and rebuild the data. The entire raw capacity will be scanned, even when not all of it was utilized. This leads to a longer rebuild time than necessary. |
14863 | Prior to lb CSI installation, the lb discovery client service must be installed and started on all K8S cluster nodes. |
14212 | OpenStack: Once a volume attach fails, the following attempts to attach it will also fail. Workaround: Remove the discovery-client configuration files for the failed volume and restart the discovery-client and Nova services. |
13064 | Following a 'replace node' operation, volumes with a single replica will be created as 'unavailable' in the new node. Note: Single replica volumes are not protected, and data will not move to the new node. Workaround: Delete single replica volumes before replacing the node, or reboot the new server after replacing the node. |
11856 | Volume and node usage metrics might show different values between REST/lbcli and Prometheus, when a volume is deleted and a node is disconnected. |
11326 | Volume metrics do not return any value for volumes that are created but do not store any data. |
10021 | Commands affecting SSD content (such as blkdiscard, nvme format) should not be executed on the Lightbits server. |